<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-16 19-08-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 47 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 3.2 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 67 kHz 19199 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,6 dBr 5,22 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 67 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/16 19.07.38 Total samples: 19199 Equivalent time: 0:15:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,3 dBr MIN: 2,6 dBr AVE: 5,22 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2025/12/16 19.07.38) 18.54 18.56 18.58 19.00 19.02 19.04 19.06 0 2 4 6 Pm [dBr]